Your voice has a chance to be heard now! scamion.com - we bring changes together.

report scam

Electricity Freedom software Projects Inc


Country United States
State Oregon
City Beaverton
Address 9450 Gemini Drive, Suite 17042
Phone 800-218-1525

Electricity Freedom software Projects Inc Reviews

  • Apr 16, 2016

SCAM

No Stars. The purchased product gives no serious information such as where to get the tank...exact pressures How to reload without losing all power and no grid hook up info as promised. It APPEARED to run a microwave and small fridge It was supposed to run your whole house.And all for 200.00 dollars supply. I am laughing at myself right now. I want so much to be a part of getting off carbon that I try anything. It hurts the cause when people are cheated like this!

  • Aug 29, 2015

I got an email about a Power Generation system called "Electricity Freedom System" that was developed by a Rich Lubbock. It was not very detailed but offered a no questions asked money return deal, so I took the plunge. I sat through all of the building videos then the final one on how to operate it. I saw the microwave and refrigerator demo but something didn't add up. There was no slow down or laboring when these loads were added.

I started looking at the whole system and realized that the compressor impeller assembly had a hose from the tank to the assembly and the exit hose returned to the tank. That means there is no pressure drop across the compressor impellars . If there is no substantial pressure drop across the impellers there will be no rotation pressure differential and therefore no rotation, never the less any ability/torque to rotate the alternator load. I as others had already notice that the "40 gallon tank" could be no more than 4 gallons - maybe a mispeak. I sent in a query to support who was supposed to answer in 24 hours or less about the lack of a pressure drop.

I also wondered why that compressor had its own motor rather than using a motor -generator/alt - since ithe extra compressor motor would create losses in the system when it was switched off to run only from the generated bio gas after the "pressure had built up for 24 hours". If it took 24 hours to build pressure it would be too slow to regenerate pressure in full run at load. It looks like the compressor motor is being nefariously powered to make it look like its working.

Through out the build and demo, I saw nor heard of any way that the rotation speed was controlled to produce 60Hz freguency required to operate appliances with frequency sensitive motors.

This as presented has to be a scam. I am a degree mechanical engineer and a PE as well.

Write a Review about Electricity Freedom software Projects Inc